Sign In | Join Free | My himfr.com
Home > Enclosure Heat Exchanger >

400W Mixed Liquid Air To Air Heat Exchanger For Outdoor Telecom Enclosure

Tianjin Estel Electronic Science and Technology Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 400W Mixed Liquid Air To Air Heat Exchanger For Outdoor Telecom Enclosure from wholesalers
     
    Buy cheap 400W Mixed Liquid Air To Air Heat Exchanger For Outdoor Telecom Enclosure from wholesalers
    • Buy cheap 400W Mixed Liquid Air To Air Heat Exchanger For Outdoor Telecom Enclosure from wholesalers
    • Buy cheap 400W Mixed Liquid Air To Air Heat Exchanger For Outdoor Telecom Enclosure from wholesalers
    • Buy cheap 400W Mixed Liquid Air To Air Heat Exchanger For Outdoor Telecom Enclosure from wholesalers
    • Buy cheap 400W Mixed Liquid Air To Air Heat Exchanger For Outdoor Telecom Enclosure from wholesalers
    • Buy cheap 400W Mixed Liquid Air To Air Heat Exchanger For Outdoor Telecom Enclosure from wholesalers
    • Buy cheap 400W Mixed Liquid Air To Air Heat Exchanger For Outdoor Telecom Enclosure from wholesalers

    400W Mixed Liquid Air To Air Heat Exchanger For Outdoor Telecom Enclosure

    Ask Lasest Price
    Brand Name : ESTEL
    Model Number : HE06-40SEH/01
    Certification : ISO9001, CE, 3C, FCC, TLC
    Price : negotiation
    Payment Terms : L/C, D/A, D/P, T/T, Western Union
    Supply Ability : 12,000 sets per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    400W Mixed Liquid Air To Air Heat Exchanger For Outdoor Telecom Enclosure


    400W Mixed Liquid Air To Air Heat Exchanger For Outdoor Telecom Enclosure


    Quick Details:


    Place of Origin: Shenzhen, China (Mainland)Rated Heat Exchange Capacity: 40W/K
    Brand Name: ESTELRated Heating Capacity:300/500W (optional)
    Model: HE06-40SEH/01Rated Input Voltage: DC48V
    Product Name: Outdoor Cabinet Heat ExchangerRated Input Current: 1.2A
    Certification: ISO9001, CE, 3C, FCC, TLCRated Input Power: 57W
    Cover Material: galvanized steelWorking Temperature: -20°C ~ +55°C
    Color: grayMTBF: 70000 hours
    Protection Level: IP55Noise: ≤62dB
    Installation Mode: door mounted, side mountedDimension W×D×H: 347×153.5×538mm
    Support OEMCooling Method: heat pipe, passive cooling

    Payment & Shipping Terms:


    Minimum Order Quantity:1 set
    Price:negotiation
    Payment Terms:L/C, D/A, D/P, T/T, Western Union
    Supply Ability:12,000 sets per month
    Delivery Time:7-10 working days
    Packaging Details:carton + foam + wooden case

    1. Specifications

    (1) Technical Parameters


    Model No.HE06-40SEH/01
    Environmental Performanceworking environmental temperature-20°C ~ 55°C
    storage working temperature-50°C ~ 70°C
    working humidity≤95%
    Thermal Performancerated heat exchange capacity40W/K
    heating input power300/500W optional

    Electrical Performance

    rated input current1.2A
    rated input power57W
    input voltageDC48V
    SafetyMTBF70000 hours
    Noise≤62dB

    Dimension Diagram: 347×153.5×538 mm (W×D×H)



    2. Description


    The HE06-40SEH/01 Mixed Working Fluid Heat Exchanger is a full automation temperature control product. It uses intelligent controller to control the whole system of the heat exchanger. According to the variation of environment temperature, the intelligent controller can automatically detect, operate and record the whole system’s operating time, power consumption, event and historical data. It can store 100 event records and 1280 historical data records, and can enquire 256 days’ daily record information.


    3. Application


    The product is widely applied in outdoor telecom cabinet, UPS cabinet, outdoor base station cabinet, outdoor advertising LED displayer, bank ATM etc.

    4. Features


    • Strong adaptability
    • High intelligence
    • High precision
    • High reliability
    • The heat exchange capacity can be set according to need
    • Low noise
    • Low energy consumption
    • Wide input voltage range: DC36 - 65V
    • With dry contact alarm output
    • Dust proof and water proof

    5. System Principle Diagram


    6. Electrical Wiring Diagram



    Diagram 3: Wiring Diagram


    Wiring Ports:


    0V -48V: power supply input (voltage input: DC36 - 65V)

    A+ B- SGND: RS485 communication interface

    AL1 AL2: general alarm output

    F+ F- : auxiliary direct ventilation control output (output voltage: DC48V)

    7. Wiring Diagram


    J1: button;

    J2: inner temperature sensor input: 1—5V, 2—inT, 3—GND;

    J3: outer temperature sensor input: 1—5V, 2—outT, 3—GND;

    J4: Prog programming port;

    JD1: DC48V input, 1—48V+, 2—48V-;

    JD2: heater power supply: 1—0V (-), 2—48V (+);

    JD3: 1, 2 - direct ventilation output, 1—48V (+), 2—0V (-);

    3, 4 - system alarm output (dry contact, close alarm);

    5, 6 - temperature alarm output (dry contact, close alarm);

    JD4: fans control port:

    fans and water pump power supply ( water pump uses 2 wire +-): 1 — 48V+, 6 — 0V-;

    inner fans control: 2 — Y1 (control output), 3 — W1 (feedback input);

    outer fans control: 4 — Y2 (control output), 5 — W2 (feedback input);

    JD5: RS485 communication port: 1 — B-, 2 — A+, 3 — SGND.


    8. Packing and Shipping



    9. Our Delivery Agent


    The goods can be shipped by sea, by air, by courier, by land, by train, etc. Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.


    10. Our Contact Information


    Mobile Phone: 0086-13752765943

    Telephone: 0086-0755 66600941

    Email: info@estel.com.cn

    lxf.estel@hotmail.com
    Skype: fiona.liang10

    Quality 400W Mixed Liquid Air To Air Heat Exchanger For Outdoor Telecom Enclosure for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Tianjin Estel Electronic Science and Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)